| Customization: | Available |
|---|---|
| Energy Efficiency Grade: | Three |
| Heat Temperature: | 50-70°C |
Shipping
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Payment Guarantee
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Secured Trading Service
Diamond Member Since 2023
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High Repeat Buyers Choice
Experienced Team
Self-branded
Exhibition Experience
More than 50% of buyers repeatedly choose the supplier
The supplier has 13 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
The supplier has 2 Self-brands, check the Audit Report for more information
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Sign In to see all verified strength labels (27)
Find Similar Products
Basic Info.
- Model NO.
- DLRK-13IBP-C1
- Work Environment
- Common Heat Pump
- Heat Source
- Air-source
- Heating Type
- Circulating Heat
- Application
- Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments
- Certification
- CE, ISO9001, RoHS
- Heat Pump
- Air Source Heat Pump
- Solar Water Heater
- Water Heater
- Heat Pump Water Heaters
- Heat Pump Air to Water
- Air Conditioner
- Made in China
- Transport Package
- Carton or Wooden Frame
- Specification
- 900*420*1226mm
- Trademark
- Hien
- Origin
- China
- HS Code
- 8418612090
- Production Capacity
- 50000pieces/Year
Packaging & Delivery
- Package Size
- 150.00cm * 120.00cm * 100.00cm
- Package Gross Weight
- 150.000kg
Product Description
Product Description

TECHNICAL ADVANTAGES
Dual Functionality: Heating and Cooling capabilities.
Heating Capacity: 16–38kW.
Advanced Compression Technology: DC inverter rotary EVI compressor
Wide Operating Temperature Range: Heating -30℃ to 28℃, Cooling 15℃ to 50℃
Cold Climate Resilience: Stable operation in -30℃ environment.
Smart Controls: Wi-Fi enabled with app for convenient remote control.
Enhanced Freeze Protection: Features 8 layers of anti-freeze design.
Wide Voltage Operation: Ultra-wide voltage operating range from 285V to 460V.
Quiet Operation: Designed for low noise levels.
Smart Defrost Technology: Frost-free operation.
Eco-Friendly: Uses R32 refrigerant.
Maximum heating water outlet temperature: 55℃.
Minimum cooling water outlet temperature: 5℃.
Heating Capacity: 16–38kW.
Advanced Compression Technology: DC inverter rotary EVI compressor
Wide Operating Temperature Range: Heating -30℃ to 28℃, Cooling 15℃ to 50℃
Cold Climate Resilience: Stable operation in -30℃ environment.
Smart Controls: Wi-Fi enabled with app for convenient remote control.
Enhanced Freeze Protection: Features 8 layers of anti-freeze design.
Wide Voltage Operation: Ultra-wide voltage operating range from 285V to 460V.
Quiet Operation: Designed for low noise levels.
Smart Defrost Technology: Frost-free operation.
Eco-Friendly: Uses R32 refrigerant.
Maximum heating water outlet temperature: 55℃.
Minimum cooling water outlet temperature: 5℃.

Heat Pump Heating and Cooling System
The heat pump is an all-in-one home solution.
In winter, it provides heating for underfloor systems, radiators, and central air conditioning.
In summer, it cools fan coils for a refreshing environment.
Efficient, energy-saving, and smart, it keeps your home comfortable all year round.

Wider Ambient Temperature Operating Range
Hien Air Source Heat Pumps operate stably within 285–460 V, designed to ensure normal use even in regions with significant voltage fluctuations.
Heating -30℃ to 28℃; Cooling 15℃ to 50℃.
Maximum heating water outlet temperature: 55℃. Minimum cooling water outlet temperature: 5℃


MORE THAN 70000 PROJECTS COMPLETED SO FAR; MORE THAN 6.5 MILLION PRODUCTS DELIVERED.
HIGHLIGHT PROJECTS
The 2008 Shanghai World Expo.
Universiade SHENZHEN 2011
The 2011 Universiade in Shenzhen.
BOAO FORUM FOR ASIA
The 2013 Boao Summit for Asia in Hainan.
The artificial island hot water project of the Hong Kong–Zhuhai–Macao Bridge in 2019.
2016 the hot water reconstruction project of Qingdao port.
BEIJING 2022
The 2022 Beijing Winter Olympic Games & Paralympic Games.
G20 2016 China
2016 the G20 Hangzhou Summit.
19th Asian Games Hangzhou 2022
2023 the Asian Games in Hangzhou
The 2008 Shanghai World Expo.
Universiade SHENZHEN 2011
The 2011 Universiade in Shenzhen.
BOAO FORUM FOR ASIA
The 2013 Boao Summit for Asia in Hainan.
The artificial island hot water project of the Hong Kong–Zhuhai–Macao Bridge in 2019.
2016 the hot water reconstruction project of Qingdao port.
BEIJING 2022
The 2022 Beijing Winter Olympic Games & Paralympic Games.
G20 2016 China
2016 the G20 Hangzhou Summit.
19th Asian Games Hangzhou 2022
2023 the Asian Games in Hangzhou
Specification
Name | DLRK-16 II BA/A1 | DLRK-18 II BA/A1 | DLRK-20 II BA/A1 | DLRK-22 II BA/A1 | DLRK-25 II BA/A1 | |
Power Supply | 380V
3N~ 50Hz | 380V
3N~ 50Hz | 380V
3N~ 50Hz | 380V
3N~ 50Hz | 380V
3N~ 50Hz | |
Anti-Electric Shock Rate | Class
I | Class
I | Class
I | Class
I | Class
I | |
Ingress Protection Rating | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | |
Condition 1 | Rated
Heating Capacity | 6200W~16500W | 8100W~18500W | 8300W~20500W | 8800W~22500W | 12000W~25000W |
Unit Type | Floor Heating Type (Outlet Water Temp.35℃) | |||||
Condition 2 | Rated
Heating Capacity | 12200W | 14000W | 15300W | 16200W | 18800W |
Rated Heating Power Input | 4080W | 5000W | 5460W | 5780W | 6550W | |
Heating COP | 2.99 | 2.80 | 2.80 | 2.80 | 2.87 | |
Condition 4 | Low
Temp. Heating Capacity | 10000W | 11400W | 12500W | 13400W | 15800W |
Low Ambient Heating Power Input | 3890W | 4650W | 5100W | 5470W | 6300W | |
Low Ambient COP | 2.57 | 2.45 | 2.45 | 2.45 | 2.51 | |
HSPF | 4.10 | 3.80 | 3.80 | 3.80 | 4.00 | |
Unit Type | Fan Coil Unit Type(Outlet Water Temp.41℃) | |||||
Condition 2 | Rated
Heating Capacity | 12200W | 14000W | 15300W | 16200W | 18800W |
Rated Heating Power Input | 4480W | 5380W | 5880W | 6350W | 7200W | |
Heating COP | 2.72 | 2.60 | 2.60 | 2.55 | 2.61 | |
Condition 4 | Low
Temp. Heating Capacity | 10000W | 11400W | 12500W | 13400W | 15800W |
Low Ambient Heating Power Input | 4280W | 5060W | 5550W | 5950W | 6950W | |
Low Ambient COP | 2.34 | 2.25 | 2.25 | 2.25 | 2.27 | |
HSPF | 3.55 | 3.40 | 3.40 | 3.40 | 3.50 | |
APF | 3.60 | 3.45 | 3.45 | 3.45 | 3.55 | |
Unit
Type | Radiator Type(Outlet Water Temp.50℃) | |||||
Condition 2 | Rated
Heating Capacity | 12200W | 14000W | 15300W | 16200W | 18800W |
Rated Heating Power Input | 5140W | 6360W | 6950W | 7360W | 8300W | |
Heating COP | 2.37 | 2.20 | 2.20 | 2.20 | 2.27 | |
Condition 4 | Low
Temp. Heating Capacity | 10000W | 11400W | 12500W | 13400W | 15800W |
Low Ambient Heating Power Input | 4850W | 5700W | 6250W | 6700W | 8000W | |
Low Ambient COP | 2.06 | 2.00 | 2.00 | 2.00 | 1.98 | |
HSPF | 2.95 | 2.80 | 2.80 | 2.80 | 2.85 | |
Rated Water Flow | 2.15m³/h | 2.58m³/h | 3.03m³/h | 3.27m³/h | 3.78m³/h | |
Condition 3 | Rated
Cooling Capacity | 12500W | 15000W | 17600W | 19000W | 22000W |
Power Input | 4170W | 5000W | 6060W | 6230W | 7100W | |
EER | 3.00 | 3.00 | 2.90 | 3.05 | 3.10 | |
CSPF | 4.60 | 4.60 | 4.85 | 4.80 | 5.02 | |
Max Power Input | 6600W | 7400W | 8200W | 9000W | 10000W | |
Max Running Current | 13A | 14A | 16A | 17A | 19A | |
Water Pressure Drop | 20kpa | 42kpa | 22kpa | 20kpa | 30kpa | |
Max Pressure on High/Low Pressure Side | 4.3/4.3Mpa | 4.3/4.3Mpa | 4.3/4.3Mpa | 4.3/4.3Mpa | 4.3/4.3Mpa | |
Allowable Discharge/Sucion Pressure | 4.3/1.2Mpa | 4.3/1.2Mpa | 4.3/1.2Mpa | 4.3/1.2Mpa | 4.3/1.2Mpa | |
Max Pressure on Evaporator | 4.3Mpa | 4.3Mpa | 4.3Mpa | 4.3Mpa | 4.3Mpa | |
Water
Pipe Connection | DN25/1" Female Thread | DN32/1¼ " Female Thread | ||||
Noise | 53dB(A) | 52dB(A) | 54dB(A) | 56dB(A) | 58dB(A) | |
Refrigerant/Charge | R32/2.5kg | R32/2.7kg | R32/3.0kg | R32/3.4kg | R32/3.6kg | |
Dimension (LxWxH)(mm) | 1000x410x1355 | 1000x410x1355 | 1000x410x1355 | 1000x410x1355 | 1100x440x1520 | |
Net Weight | 109kg | 111kg | 119kg | 123kg | 153kg | |
Heat Pump Testing Conditions
Condition 1:Outdoor Air Temp. : DB 7°C / WB 6°C ,Outlet Water Temp.45℃
Condition 2:Outdoor Air Temp. : DB -12°C / WB -13.5°C
Condition 3:Outdoor Air Temp. : DB 35°C /-,Outlet Water Temp.7℃
Condition 4:Outdoor Air Temp. : DB -20°C /-
Condition 2:Outdoor Air Temp. : DB -12°C / WB -13.5°C
Condition 3:Outdoor Air Temp. : DB 35°C /-,Outlet Water Temp.7℃
Condition 4:Outdoor Air Temp. : DB -20°C /-
Name | DLRK-28 II BA/A1 | DLRK-31 II BA/A1 | DLRK-33 II BA/A1 | DLRK-38IIBA/A1 | DLRK-45 II BA/A1 | |
Power Supply | 380V
3N~ 50Hz | 380V
3N~ 50Hz | 380V
3N~ 50Hz | 380V
3N~ 50Hz | 380V
3N~ 50Hz | |
Anti-Electric Shock Rate | Class
I | Class
I | Class
I | Class
I | Class
I | |
Ingress Protection Rating | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | |
Condition 1 | Rated
Heating Capacity | 12500W~28000W | 13000W~31000W | 13500W~33000W | 15000W~38000W | 17200W~45000W |
Unit Type | Floor Heating Type(Outlet Water Temp.35℃) | |||||
Condition 2 | Rated
Heating Capacity | 21000W | 23000W | 24600W | 28200W | 33000W |
Rated Heating Power Input | 7500W | 7900W | 8800W | 9700W | 11500W | |
Heating COP | 2.80 | 2.91 | 2.80 | 2.91 | 2.87 | |
Condition 4 | Low
Temp. Heating Capacity | 17800W | 19200W | 20600W | 23500W | 27700W |
Low Ambient Heating Power Input | 7250W | 7600W | 8400W | 9300W | 10950W | |
Low Ambient COP | 2.46 | 2.53 | 2.45 | 2.53 | 2.53 | |
HSPF | 3.90 | 3.90 | 3.80 | 3.80 | 3.85 | |
Unit Type | Fan Coil Unit Type(Outlet Water Temp.41℃) | |||||
Condition 2 | Rated
Heating Capacity | 21000W | 23000W | 24600W | 28200W | 33000W |
Rated Heating Power Input | 8250W | 8700W | 9600W | 10700W | 12530W | |
Heating COP | 2.55 | 2.64 | 2.56 | 2.64 | 2.63 | |
Condition 4 | Low
Temp. Heating Capacity | 17800W | 19200W | 20600W | 23500W | 27700W |
Low Ambient Heating Power Input | 8000W | 8300W | 9100W | 10200W | 11930W | |
Low Ambient COP | 2.23 | 2.31 | 2.26 | 2.30 | 2.32 | |
HSPF | 3.40 | 3.50 | 3.40 | 3.40 | 3.45 | |
APF | 3.45 | 3.55 | 3.45 | 3.45 | 3.50 | |
Unit
Type | Radiator Type(Outlet Water Temp.50℃) | |||||
Condition 2 | Rated
Heating Capacity | 21000W | 23000W | 24600W | 28200W | 33000W |
Rated Heating Power Input | 9500W | 9900W | 11000W | 12100W | 14270W | |
Heating COP | 2.21 | 2.32 | 2.24 | 2.33 | 2.31 | |
Condition 4 | Low
Temp. Heating Capacity | 17800W | 19200W | 20600W | 23500W | 27700W |
Low Ambient Heating Power Input | 9200W | 9400W | 10400W | 11400W | 13520W | |
Low Ambient COP | 1.93 | 2.04 | 1.98 | 2.06 | 2.05 | |
HSPF | 2.80 | 2.95 | 2.85 | 2.85 | 2.90 | |
Rated Water Flow | 4.13m³/h | 4.47m³/h | 4.82m³/h | 5.33m³/h | 6.36m³/h | |
Condition 3 | Rated
Cooling Capacity | 24000W | 26000W | 28000W | 31000W | 37000W |
Power Input | 8200W | 8600W | 10000W | 11000W | 12750W | |
EER | 2.93 | 3.02 | 2.80 | 2.82 | 2.90 | |
CSPF | 4.92 | 4.65 | 4.50 | 4.52 | 4.70 | |
Max Power Input | 11200W | 12500W | 13500W | 15800W | 18700W | |
Max Running Current | 21.5A | 24A | 26A | 30A | 32A | |
Water Pressure Drop | 35kpa | 30kpa | 35kpa | 35kpa | 36kpa | |
Max Pressure on High/Low Pressure Side | 4.3/4.3Mpa | 4.3/4.3Mpa | 4.3/4.3Mpa | 4.3/4.3Mpa | 4.3/4.3Mpa | |
Allowable Discharge/Sucion Pressure | 4.3/1.2Mpa | 4.3/1.2Mpa | 4.3/1.2Mpa | 4.3/1.2Mpa | 4.3/1.2Mpa | |
Max Pressure on Evaporator | 4.3Mpa | 4.3Mpa | 4.3Mpa | 4.3Mpa | 4.3Mpa | |
Water
Pipe Connection | DN32/1¼ " Female Thread | |||||
Noise | 58.5dB(A) | 59dB(A) | 59.5dB(A) | 60dB(A) | 60.5dB(A) | |
Refrigerant/Charge | R32/3.6kg | R32/4.0kg | R32/4.0kg | R32/4.8kg | R32/6.5kg | |
Dimension (LxWxH)(mm) | 1100x440x1520 | 1100x440x1520 | 1100x440x1520 | 1200x430x1550 | 1540x570x2100 | |
Net Weight | 153kg | 162kg | 162kg | 182kg | 307kg | |
Exhibition

Global Presence with Hien From Beijing ISH to Milan MCE, from Frankfurt ISH to Birmingham Installer Show
Hien is redefining global standards in sustainable climate control — one heat pump at a time. At the world's top HVAC exhibitions, our eye-catching booths showcase cutting-edge heat pump technologies and a track record of over 70,000 successful solutions delivered worldwide. We're not just attending — we're driving the transformation toward energy-efficient, low-carbon living.
Meet us at:
ISH Germany • Hall 12.0 E29 • 156 m²
ISH China & CIHE • E4-03 • 400 m²
MCE Milan • Hall 3 M50 • 60 m²
Installer Show Birmingham • 2024 & 2025 • Two booths
Warsaw HVAC Expo • E2.16 • 69 m²
Heat Pump Technologies Milan • C22 • 32 m²
ISH China & CIHE • E4-03 • 400 m²
MCE Milan • Hall 3 M50 • 60 m²
Installer Show Birmingham • 2024 & 2025 • Two booths
Warsaw HVAC Expo • E2.16 • 69 m²
Heat Pump Technologies Milan • C22 • 32 m²
Company Profile

ABOUT HIEN
Founded in 1992, Hien firstly started as an electronic component manufacturer. With a registered capital of 300 million RMB, Hien entered the air source industry in 2000. It is a leading enterprise of air source heat pumps in the area of product R & D, production, sales, and after-sales service. Hien owns one of the largest production bases of heat pumps in China, as well as the CANS-certified state-level comprehensive laboratory.
Production Experience | Total foorspace | Cooperated suppliers | ODM services | R&D Team | Transaction Amount |
30+years | (51,234)square meter | (5300+) | available | 100+ Workers | 800,000,000+ |

Innovation Engine Behind Hien's Heat Pump Excellence
At Hien, our R&D team is the driving force behind breakthrough heat pump solutions. With over 130 invention patents, 106 technical experts, and 25 years of deep experience in core technologies, we turn ideas into high-performance, energy-efficient systems.
Our facilities span 5,000 m², equipped with tools valued over ¥20 million, supporting expertise in thermal power, electrical engineering, energy management, and more. Backed by two R&D centers and a national-level postdoctoral research station, we don't just follow trends — we define them.
From concept to deployment, our team customizes solutions that meet real-world demands, empowering our global partners to lead in sustainability.
FAQ
Q.Are you a trading company or manufacturer?
A: We are a heat pump manufacturer in China.We specialized in heat pump design/ manufacturing for more than 25 years.
A: We are a heat pump manufacturer in China.We specialized in heat pump design/ manufacturing for more than 25 years.
Q.Can i ODM/ OEM and print my own logo on the products?
A: Yes, Through 25 years research and development of heat pump, hien technical team is professional and experienced to offer customized solution for OEM,ODM customer, which is one of our most competitive advantage.
If above online heat pump does not match your requirements, please do not hesitate to send message to us, we have hundreds of heat pump for optional, or customizing heat pump based on demands, it is our advantage!
If above online heat pump does not match your requirements, please do not hesitate to send message to us, we have hundreds of heat pump for optional, or customizing heat pump based on demands, it is our advantage!
Q.How do l know if your heat pump are good quality?
A: Sample order is acceptable for testing your market and checking our quality And we have strict quality control systems from raw material incoming until finished product delivery out.
A: Sample order is acceptable for testing your market and checking our quality And we have strict quality control systems from raw material incoming until finished product delivery out.
Q.Do you test all the goods before delivery?
A: Yes, we have 100% test before delivery. If you need any assistance, please feel free to contact us.
A: Yes, we have 100% test before delivery. If you need any assistance, please feel free to contact us.
Q: What certifications do your heat pump has?
A: Our heat pump have CEcertification, MCS,ISO 14001, ISO 45001, and ISO 9001 certification.
A: Our heat pump have CEcertification, MCS,ISO 14001, ISO 45001, and ISO 9001 certification.
Q: For a customized heat pump, how long is the R&D time (Research& Development time)?
A: Normally, 10~50 business days, it depends on requirements, just some modification on standard heat pump or a totally new design item.
If you are interested in this product,please fill in the below and send us,we will reply you and also send you the latest product catalog and latest quotation within 1 hour!
Send your message to this supplier
People who viewed this also viewed
Product Groups
Find Similar Products By Category
- Supplier Homepage
- Products
- Heating And Cooling Heat Pump
- Residential Heating & Cooling Series
- Factory Wholesale OEM Air Source Heat Pump for Sale Domestic Heatpump Heating Cooling System Water Heaters
Related Categories
Hot Searches
More